- CGA
- TQI
- NQI
Objective: To Increase Mill Output
(Product Used: CGA & TQI)
OPC | Blank | CGA | TQI |
---|---|---|---|
Mill Output (TPH) | 200 | 220 | 250 |
% Mill Output | 100 | 110 | 125 |
Specific Power (kWh/t) | 30 | 27.5 | 24.5 |
Blaine (m2/kg) | 310 | 312 | 280 |
IST/ FST (mins) | 150/ 250 | 140/ 240 | 125/ 230 |
Mortar Strength (1 day) | 22 | 23 | 22.5 |
Mortar Strength (3 days) | 33 | 33 | 34 |
Mortar Strength (7 days) | 47 | 48 | 48 |
Mortar Strength (28 days) | 62 | 62 | 61 |
Objective: To Increase Strength (Flyash%)
(Product Used: NQI & TQI)
PPC | Blank | NQI | TQI |
---|---|---|---|
Mill Output (TPH) | 230 | 265 | 260 |
% Mill Output | 100 | 115 | 113 |
Blaine (m2/kg) | 350 | 350 | 350 |
Specific Power (kWh/t) | 28 | 24.5 | 25 |
Flyash % | 30 | 34 | 34 |
IST/ FST (mins) | 210/ 300 | 150/ 245 | 150/ 245 |
Mortar Strength (1 day) | 10.5 | 11 | 12 |
Mortar Strength (3 days) | 26 | 27 | 28 |
Mortar Strength (7 days) | 35 | 36.5 | 38 |
Mortar Strength (28 days) | 53 | 55 | 56 |
Objective: To Increase Strength (Slag%)
(Product Used: TQI)
PPC | Blank | TQI |
---|---|---|
Mill Output (TPH) | 150 | 154 |
Slag % | 50 | 55 |
Blaine (m2/kg) | 380 | 382 |
IST/ FST (mins) | 190/ 255 | 165/ 220 |
Mortar Strength (1 day) | 8.5 | 9.0 |
Mortar Strength (3 days) | 24 | 26 |
Mortar Strength (7 days) | 33 | 38 |
Mortar Strength (28 days) | 41 | 51.5 |